DESCRIPTION
- Measuring range is wide due to the integration of Piezo and Pirani sensors
- Better accuracy and prime resolution over the whole measuring range
- Brilliant reproducibility and stability
- Digital RS485 interface and additional analog output signal 1.5-8.58 V
- Baud rate detected automatically 9.6 kBd to 115 kBd
- Two separate, potential-free relay switch points
- Sensor heads can be replaced easy with stored calibration data
- Stainless steel small flange DN 16 KF and DN 16 CF-F used as vacuum connection
VARIENTS
- VSR53D Vacuum Transducer ● DN16KF
- VSR53DL Vacuum Transducer ● DN16KF ● LCD Display
- VSR53E Vacuum Transducer ● DN16KF ● EtherCAT
- VSR54D Vacuum Transducer ● DN16CF-F
- VSR54DL Vacuum Transducer ● DN16CF-F ● LCD Display
- VSR54E Vacuum Transducer ● DN16CF-F ● EtherCAT
VSP Vacuum Transducer Pirani 1000 to 1e-4 mbar
Precise measurements in range of fine vacuums can be achieved by the VSP Pirani vacuum transducer with robust helix filament. The process control is safe, precise and cost effective with the help of the cutting edge technology of smartline vacuum gauges.
DESCRIPTION
- Long lasting Pirani helix filament
- Better resolution and accuracy
- Pirani filament is shielded against oil and solvent vapors by a metal screen
- Digital RS485 interface and EtherCAT
- Baud rate detected automatically 9.6 kBd to 115 kBd
- Two separate, potential-free relay switch points
- Sensor heads can be replaced easy with stored calibration data
Varients
- VSP63D Vacuum Transducer ● DN16KF
- VSP63DL Vacuum Transducer ● DN16KF ● LCD display
- VSP63E Vacuum Transducer ● DN16KF ● EtherCAT
- VSP64D Vacuum Transducer ● DN16CF-F
- VSP64DL Vacuum Transducer ● DN16CF-F ● LCD display
- VSP64E Vacuum Transducer ● DN16CF-F ● EtherCAT
VSM Vacuum Transducer● Pirani/Cold Cathode ● 1000 to 5e-9 mbar
Absolute pressure from atmospheric pressure to ultrahigh vacuum is measured by the digital combination transducer VSM (Pirani/Cold cathode).An optional interplay between both sensors is managed by the microcontroller intelligence. The process control is safe, precise and cost effective with the help of the cutting edge technology of smartline vacuum gauges.
Description
- Measuring range is wide due to the combination Pirani / cold cathode sensor
- Operation of cold cathode at lower pressure is possible by the Pirani with extended range and increases the lifetime
- Durable sensor design, undisturbed with inrush of air
- Digital RS485 interface and EtherCAT output signal 1.819-8.6 V
- Baud rate detected automatically 9.6 kBd to 115 kBd
- Two separate, potential-free relay switch points
- Sensor heads can be replaced easy with stored calibration data
Varients
- VSM77D Vacuum Transducer ● DN25KF
- VSM77DL Vacuum Transducer ● DN25KF ● LCD display
- VSM77E Vacuum Transducer ● DN25KF ● EtherCAT
- VSM79D Vacuum Transducer ● DN40CF-F
- VSM79DL Vacuum Transducer ● DN40CF-F ● LCD display
- VSM79E Vacuum Transducer ● DN40CF-F ● EtherCAT
4VSH Vacuum Transducer● Pirani / Hot Cathode ● 1000 to 5e-10 mbar
Absolute pressure from atmospheric pressure to ultrahigh vacuum is measured by the digital combination transducer VSM (Pirani/Hot cathode).An optional interplay between both sensors is managed by the microcontroller intelligence. The process control is safe, precise and cost effective with the help of the cutting edge technology of smartline vacuum gauges.
DESCRIPTION
Operation of hot cathode at lower pressure is possible by the Pirani with extended range and increases the lifetime
- Brilliant accuracy and ability to repeat
- Bayard-Alpert with blowing resistant, double filament coated yttrium, undisturbed with inrush of air
- Digital RS485 interface and analog output signal 1.219-8.6 V
- Baud rate detected automatically 9.6 kBd to 115 kBd
- Two separate, potential-free relay switch points
- Sensor heads can be replaced easy with stored calibration data
VARIENTS
- VSH88D Vacuum Transducer ● DN40KF
- VSH88DL Vacuum Transducer ● DN40KF ● LCD display
- VSH88E Vacuum Transducer ● DN40KF ● EtherCAT
- VSH89DL Vacuum Transducer ● DN40CF-F ● LCD display
- VSH89E Vacuum Transducer ● DN40CF-F ● EtherCAT
- VSH89D Vacuum Transducer ● DN40CF-F
VD12 Vacuum Display And Control Unit
In apparatus and plant engineering or special equipment construction, the 2 Channels D12 intelligent control unit is ideally used.
DESCRIPTION
- Concurrent control of 2 measuring channels
- Can be integrated with all Smartline and 0-10 V Analogline transducers
- Easy performance by menu driven operator guidance
- 2 potential-free relay switches
- Huge graphic LCD display with background illumination
- Process documentation and setpoint programming by USB interface
- VacuGraph software: vacuum processes are documented and evaluated, remote control
VARIENTS
- VD1253P ● Set VD12 with VSR53D ● Piezo/Pirani ● 1200 to 1e-4 mbar
- VD1263P ● Set VD12 with VSP63D ● Pirani ● 1000 to 1e-4 mbar
- VD1277P ● Set VD12 with VSM77D ●Pirani/Cold Cathode ● 1000 to 5e-9 mbar
- VD1288P ● Set VD12 with VSH88D ●Pirani/Hot Cathode ● 1000 to 5e-10 mbar
- VD12S2 Vacuum Display And Control Unit
VD10 Vacuum Display And Control Unit ● 4 Channels
The most ideal for upto four Smartline transmitters is the VD20 vacuum display and control unit which is used in apparatus and plant engineering or special equipment construction.
DESCRIPTION
- Huge graphic LCD display with background illumination, pressure display in mbar, Torr, hPa
- Concurrent control of up to 4 measuring channels
- Simple to use, menu-driven operator instructions
- 8 dry relay switching points
- 2 function keysb that are programmable
- Process documentation by USB interface
- VacuGraph software: vacuum processes are documented and evaluated remote control