- The FKM sealing makes the ceramic sensor chemically resistant
- Highly accurate, reliable and stable
- Response time is short
- Not affected by contamination
- Compensates temperature
- Standardized, linear output signal current or voltage
- Easily connected to PLCs and other controllers of the system
- Vacuum connection over a stainless steel small flange DN 16 ISO-KF with G1/4 female thread
- VSC43MA4 Vacuum Transducer ● 4-20 mA output
- VSC43MV Vacuum Transducer ● 0-10 V output

- Superb accuracy
- High resolution
- Aluminium oxide ceramic sensor is resistant to corrosion
- Measurement is independent of gas type
- Resistant to dirt
- Robust metal housing with protection class IP54
- Vacuum connection over a stainless steel small flange DN 16 ISO-KF with G1/4 female thread

- Highly reliable and excellently reproducible
- Immensely compact to suit industrial applications
- Large measuring range with higher resolution in the range of rough vacuums
- Good resistance against oil and solvent capors is provided by the filament which is protected by a metal screen
- Precise push button digital adjustment on zero pressure and atmosphere
- Low power consumption
- Impulse mode reduces self heating of measuring chamber
- Metal sealed stainless steel sensor is ideal for UHV applications
- VSP63MA4 Vacuum Transducer ● DN16KF ● 4-20 mA output
- VSP63MV Vacuum Transducer ● DN16KF ● 0-10V output
- VSP64MV Vacuum Transducer ● DN16CF-F ● 0-10 V output

- Ideal for corrosive media
- Highly reliable
- Chemical resistance is high due to the platinum rodium filament
- Good resistance against oil and solvent vapors due to the Pirani sensor which is protected by a metal screen
- Resolution is high even in he rough vacuum range
- Precise push button digital adjustment on zero pressure and atmosphere
- Measurements are stable due to maximum temperature compensation. It is ideal for UHV applications due to the metal sealed sensor.

- Economical Pirani sensor
- Excellent long term stability
- Durable sensor, elastic helix filament
- Filament protected by a metal screen from condensing solvents
- Sensor is pre-adjusted
- Extremely minute sensor volume
- Screwable, electric connector
- Evaluation circuit attainable on request
- VSP841 Passive Vacuum Sensor ● DN16KF
- VSP842 Passive Vacuum Sensor ● 1/8 NPT thread

- 2- or 3-state-control: 2 relay switch points (switch-over), adaptable over the entire range
- Intuitive operation
- Large, high-contrast LED-display
- Long table runs due to the Thyracont transducers with 4 - 20 mA signal output
- Foil-sealed front panel
- Panel mounting through DIN case 96 x 48 mm
- Process control and documentation through USB interface for
- VD62P230 ● Set VD6S2230 with VSC43MA4 ● 1200 to 1 mbar
- VD64P230 ● Set VD6S2230 with VSP63MA4 ● 1000 to 1e-4 mbar
- VD6S2115 Vacuum Display and Control Unit ● 115 VAC
- VD6S2230 Vacuum Display and Control Unit ● 230 VAC

- Simultaneously controls 2 measuring channels
- Can be integrated with all Smartline and 0-10 V Analogline transducers
- Easy operation by menu driven operator guidance
- 2 potential-free relay switches
- Huge graphic LCD display with background illuminating
- Process documentation and setpoint programming through USB interface
- VacuGraph software: Documentation and evaluation of vacuum processes, remote control
- VD122P ● Set VD12 with VSC43MV ● 1400 to 1 mbar
- VD124P ● Set VD12 with VSP63MV ● 1000 to 1e-4 mbar
- VD12S2 Vacuum Display And Control Unit
- Unmatched Accuracy: Our transducers provide highly accurate measurements, ensuring you get the precise data you need.
- Robust and Reliable: Built to withstand harsh conditions, our products resist dirt, contamination, and various gas types.
- Quick Response Time: With a short response time, you can trust our transducers to deliver real-time, reliable data.
- Chemical Resistance: Thanks to the FKM sealing, the ceramic sensor is highly chemical resistant.
- High Accuracy: Delivers reliable and stable readings.
- Quick Response: Short response time for real-time data.
- Temperature Compensation: Maintains accuracy across varying temperatures.
- Easy Integration: Compatible with PLCs and other system controllers.
- Stainless Steel Connection: Comes with a DN 16 ISO-KF flange and G1/4 female thread.
- VSC43MA4: Vacuum Transducer with 4-20 mA output.
- VSC43MV: Vacuum Transducer with 0-10 V output.
- Superb Accuracy: Provides high-resolution measurements.
- Corrosion Resistance: The aluminium oxide ceramic sensor is highly resistant to corrosion.
- Gas Type Independence: Measurement is independent of gas type, even below 20 mbar.
- Robust Housing: Metal housing with IP54 protection.
- Stainless Steel Connection: Features a DN 16 ISO-KF flange and G1/4 female thread.
- High Reliability: Reproducible and stable measurements.
- Compact Design: Ideal for industrial applications.
- Wide Measuring Range: Higher resolution in rough vacuums.
- Oil and Solvent Vapour Resistance: Filament is protected by a metal screen.
- Digital Adjustment: Precise push-button zero pressure and atmosphere adjustment.
- Low Power Consumption: Efficient operation with reduced self-heating.
- VSP63MA4: Vacuum Transducer with DN16KF and 4-20 mA output.
- VSP63MV: Vacuum Transducer with DN16KF and 0-10V output.
- VSP64MV: Vacuum Transducer with DN16CF-F and 0-10 V output.
- Dual Channel Control: Manages two measuring channels simultaneously.
- Easy Operation: User-friendly, menu-driven guidance.
- Relay Switches: Features two potential-free relay switches.
- Large Display: Graphic LCD with background illumination for easy reading.
- USB Interface: This is for process documentation and setpoint programming.
- VacuGraph Software: Facilitates documentation, evaluation, and remote control of vacuum processes.
- Accuracy: Ensure the device provides the precision you need.
- Durability: Check if it can withstand harsh conditions and contamination.
- Response Time: Look for a transducer with a quick response for real-time data.
- Integration: Make sure it's compatible with your existing systems.
- Support: Opt for a brand that offers reliable customer support and after-sales service.
Frequently Asked Questions
What output signal types are available for Thyracont analog vacuum transducers and how do they integrate with industrial control systems?
Thyracont analog vacuum transducers are available with 0-10V and 4-20mA analog output signals, as well as RS485 digital communication interfaces. These are directly compatible with standard PLCs, DCS platforms, and SCADA systems used in industrial process control. The 4-20mA current loop output is preferred for long cable runs in industrial environments due to its noise immunity. Ezzi Vision can advise on signal compatibility with your control system.
What calibration traceability is available for vacuum transducers supplied by Ezzi Vision for metrology-critical applications?
Thyracont vacuum transducers are factory-calibrated to traceable standards. For metrology-critical applications in pharmaceutical, aerospace, or calibration laboratories, Ezzi Vision can arrange NATA-accredited calibration services in Australia. Calibration certificates with traceability to national standards are available on request to support your quality management system requirements.
How do I specify the correct vacuum transducer for a multi-point vacuum monitoring installation in an industrial facility?
For multi-point installations, key specification parameters include: vacuum pressure range at each measurement point, required output signal type (analog vs digital), process gas compatibility, operating temperature range, connection size and type (KF16, KF25, KF40, or threaded), and whether a combined Pirani/cold cathode sensor is needed for wide-range measurement. Ezzi Vision's instrumentation team can develop a complete transducer specification across all measurement points.
What is the ingress protection (IP) rating of Thyracont vacuum transducers and are they suitable for industrial plant environments?
Thyracont vacuum transducers are designed for industrial environments, with appropriate IP ratings for their respective models. For harsh plant environments with dust, moisture, or chemical exposure, Ezzi Vision can specify transducer models with appropriate housing protection. Contact their technical team with your environmental classification to confirm the suitable IP-rated model.
Can vacuum transducers from Ezzi Vision be supplied with ATEX certification for hazardous area installations?
ATEX-certified vacuum measurement solutions are available for hazardous area installations (Zone 1 and Zone 2) involving flammable gases or vapours. If your process involves explosive atmospheres, advise Ezzi Vision of your ATEX zone classification so they can specify a compliant transducer or intrinsically safe barrier solution.
What quantity pricing is available for vacuum transducers when equipping a large vacuum system installation with multiple measurement points?
Ezzi Vision offers volume pricing for multi-unit transducer orders on large vacuum system installations. For projects requiring 5 or more transducers, contact their B2B sales team with a project specification to receive a consolidated quotation. Staged delivery scheduling can also be arranged to align with your installation programme.
Choose Ezzi Vision
Vacuum, Lithography, Thin-Film Experts
Experience top-tier repair and maintenance services for glovebox and vacuum equipment, backed by industry expertise across Australia.
Contact Us